Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Lab Chip ; 23(13): 3016-3033, 2023 06 28.
Artigo em Inglês | MEDLINE | ID: mdl-37294576

RESUMO

Droplet injection strategies are a promising tool to reduce the large amount of sample consumed in serial femtosecond crystallography (SFX) measurements at X-ray free electron lasers (XFELs) with continuous injection approaches. Here, we demonstrate a new modular microfluidic droplet injector (MDI) design that was successfully applied to deliver microcrystals of the human NAD(P)H:quinone oxidoreductase 1 (NQO1) and phycocyanin. We investigated droplet generation conditions through electrical stimulation for both protein samples and implemented hardware and software components for optimized crystal injection at the Macromolecular Femtosecond Crystallography (MFX) instrument at the Stanford Linac Coherent Light Source (LCLS). Under optimized droplet injection conditions, we demonstrate that up to 4-fold sample consumption savings can be achieved with the droplet injector. In addition, we collected a full data set with droplet injection for NQO1 protein crystals with a resolution up to 2.7 Å, leading to the first room-temperature structure of NQO1 at an XFEL. NQO1 is a flavoenzyme associated with cancer, Alzheimer's and Parkinson's disease, making it an attractive target for drug discovery. Our results reveal for the first time that residues Tyr128 and Phe232, which play key roles in the function of the protein, show an unexpected conformational heterogeneity at room temperature within the crystals. These results suggest that different substates exist in the conformational ensemble of NQO1 with functional and mechanistic implications for the enzyme's negative cooperativity through a conformational selection mechanism. Our study thus demonstrates that microfluidic droplet injection constitutes a robust sample-conserving injection method for SFX studies on protein crystals that are difficult to obtain in amounts necessary for continuous injection, including the large sample quantities required for time-resolved mix-and-inject studies.


Assuntos
Lasers , Proteínas , Humanos , Cristalografia por Raios X , Proteínas/química , Injeções , NAD(P)H Desidrogenase (Quinona)
2.
Biophys Rep (N Y) ; 2(4): 100081, 2022 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-36425668

RESUMO

With advances in X-ray free-electron lasers (XFELs), serial femtosecond crystallography (SFX) has enabled the static and dynamic structure determination for challenging proteins such as membrane protein complexes. In SFX with XFELs, the crystals are typically destroyed after interacting with a single XFEL pulse. Therefore, thousands of new crystals must be sequentially introduced into the X-ray beam to collect full data sets. Because of the serial nature of any SFX experiment, up to 99% of the sample delivered to the X-ray beam during its "off-time" between X-ray pulses is wasted due to the intrinsic pulsed nature of all current XFELs. To solve this major problem of large and often limiting sample consumption, we report on improvements of a revolutionary sample-saving method that is compatible with all current XFELs. We previously reported 3D-printed injection devices coupled with gas dynamic virtual nozzles (GDVNs) capable of generating samples containing droplets segmented by an immiscible oil phase for jetting crystal-laden droplets into the path of an XFEL. Here, we have further improved the device design by including metal electrodes inducing electrowetting effects for improved control over droplet generation frequency to stimulate the droplet release to matching the XFEL repetition rate by employing an electrical feedback mechanism. We report the improvements in this electrically triggered segmented flow approach for sample conservation in comparison with a continuous GDVN injection using the microcrystals of lysozyme and 3-deoxy-D-manno-octulosonate 8-phosphate synthase and report the segmented flow approach for sample injection applied at the Macromolecular Femtosecond Crystallography instrument at the Linear Coherent Light Source for the first time.

3.
J Appl Crystallogr ; 55(Pt 1): 1-13, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35153640

RESUMO

Serial femtosecond crystallography (SFX) is a powerful technique that exploits X-ray free-electron lasers to determine the structure of macro-molecules at room temperature. Despite the impressive exposition of structural details with this novel crystallographic approach, the methods currently available to introduce crystals into the path of the X-ray beam sometimes exhibit serious drawbacks. Samples requiring liquid injection of crystal slurries consume large quantities of crystals (at times up to a gram of protein per data set), may not be compatible with vacuum configurations on beamlines or provide a high background due to additional sheathing liquids present during the injection. Proposed and characterized here is the use of an immiscible inert oil phase to supplement the flow of sample in a hybrid microfluidic 3D-printed co-flow device. Co-flow generation is reported with sample and oil phases flowing in parallel, resulting in stable injection conditions for two different resin materials experimentally. A numerical model is presented that adequately predicts these flow-rate conditions. The co-flow generating devices reduce crystal clogging effects, have the potential to conserve protein crystal samples up to 95% and will allow degradation-free light-induced time-resolved SFX.

4.
Gait Posture ; 85: 258-265, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33626450

RESUMO

BACKGROUND: Several multi-segment foot models have been developed to evaluate foot and ankle motion using skin-marker motion analysis. However, few multi-segment models have been evaluated against a reference standard to establish kinematic accuracy. RESEARCH QUESTION: How accurately do skin-markers estimate foot and ankle motion for the modified Shriners Hospitals for Children Greenville (mSHCG) multi-segment foot model when compared against the reference standard, dual fluoroscopy (DF), during gait, in asymptomatic participants? METHODS: Five participants walked overground as full-body skin-marker trajectory data and DF images of the foot and shank were simultaneously acquired. Using the mSHCG model, ankle and midfoot angles were calculated throughout stance for both motion analysis techniques. Statistical parametric mapping assessed differences in joint angles and marker positions between skin-marker and DF motion analysis techniques. Paired t tests, and linear regression models were used to compare joint angles and range of motion (ROM) calculated from the two techniques. RESULTS: In the coronal plane, the skin-marker model significantly overestimated ROM (p = 0.028). Further, the DF model midfoot ROM was significantly positively related to differences between DF and skin-marker midfoot angles (p = 0.035, adjusted R2 = 0.76). In the sagittal plane, skin-markers underestimated ankle angles by as much as 7.26°, while midfoot angles were overestimated by as much as 9.01°. However, DF and skin-marker joint angles were not significantly different over stance. Skin-markers on the tibia, calcaneus, and fifth metatarsal had significantly different positions than the DF markers along the direction of walking for isolated portions that were less than 10 % of stance. Euclidean distances between DF and skin-markers positions were less than 9.36 mm. SIGNIFICANCE: As the accuracy of the mSHCG model was formerly unknown, the results of this study provide ranges of confidence for key angles calculated by this model.


Assuntos
Articulação do Tornozelo/diagnóstico por imagem , Pé/diagnóstico por imagem , Modalidades de Fisioterapia , Caminhada/fisiologia , Articulação do Tornozelo/anatomia & histologia , Fenômenos Biomecânicos , Fluoroscopia , Pé/anatomia & histologia , Humanos , Amplitude de Movimento Articular , Padrões de Referência , Reprodutibilidade dos Testes , Adulto Jovem
5.
Opt Express ; 28(15): 21749-21765, 2020 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-32752448

RESUMO

Gas dynamic virtual nozzles (GDVNs) produce microscopic flow-focused liquid jets and droplets and play an important role at X-ray free-electron laser (XFEL) facilities where they are used to steer a stream of hydrated biomolecules into an X-ray focus during diffraction measurements. Highly stable and reproducible microjet and microdroplets are desired, as are flexible fabrication methods that enable integrated mixing microfluidics, droplet triggering mechanisms, laser illumination, and other customized features. In this study, we develop the use of high-resolution 3D nano-printing for the production of monolithic, asymmetric GDVN designs that are difficult to fabricate by other means. We also develop a dual-pulsed nanosecond image acquisition and analysis platform for the characterization of GDVN performance, including jet speed, length, diameter, and directionality, among others. We show that printed GDVNs can form microjets with very high degree of reproducibility, down to sub-micron diameters, and with water jet speeds beyond 170 m/s.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA